ClubEnsayos.com - Ensayos de Calidad, Tareas y Monografias
Buscar

Medidores De Diafragma


Enviado por   •  18 de Marzo de 2013  •  1.142 Palabras (5 Páginas)  •  337 Visitas

Página 1 de 5

IM 3701.1

Medium/Large Diaphragm Meter Installation Instructions

ISSUED July, 2000

METER IDENTIFICATION

The inlet and outlet of the meter are plainly marked on the top. The maximum working pressure of the meter is given on the manufacturer’s badge. It is extremely important that the maximum working pressure not be exceeded at any time. The rated capacity of the meter at ½” and 2” water column differential pressure is also marked on the badge. When any particular information is desired regarding this meter, please refer to the serial number of the meter, which is embossed on the bottom of the manufacturer’s badge.

Manufacturer’s Badge

GAS PURITY

In cases where condensation may collect in the line on the upstream side of the meter, the line should be supplied with suitable drips to collect the condensate and prevent it from entering the meter. This precaution will eliminate difficulties due to liquid entering the meter and eliminate the possibility of damage, which may occur due to freezing of the liquids.

American Meter Company produces meters suitable for measuring high purity gases. Prior to system startup, the meter should be purged with the gas and its outlet stream monitored until the required purity level is achieved. After such point, further component out-gassing will be at a diminishing rate. The primary absorbed or volatilized gases would be water vapor, air, and smaller amounts of hydrocarbons. The flow rate, temperature, and required purity level of each process is unique and the purchaser must determine a satisfactory purge period.

INSTALLATION

The pipe leading to the inlet of the meter should be blown clean before the meter is connected to it. In many cases, after meters are connected, pipe turnings, scale, dirt, liquids and other foreign materials are blown into the meter when the gas is admitted. This material will collect in the top of the meter, on the valves, and in the bearings. If it does not create serious damage, it will increase wear, causing the meter to lose its accuracy.

Care should be exercised in blowing drips. In some cases, blowing drips on the outlet side of the meter has damaged the internal mechanisms of meters. A sudden reduction in pressure due to blowing the drips or opening the outlet valve too quickly may increase the velocity through the meter to an excessive rate, which may strain or break some of the working parts.

CAUTION: Extreme care should be taken when pressuring this high capacity meter on start-up. Excessive differential pressures across diaphragms, channels and partitions can result in serious damage or deformation. The following procedure should be used in order to prevent damage to the meter.

INSTALLATION WITH BY-PASS

WITH GAS FLOWING THROUGH THE BY-PASS, VERY SLOWLY ON ALL OPERATIONS:

1. CRACK THE METER OUTLET VALVE TO PRESSURIZE THE METER.

2. CRACK THE METER INLET VALVE UNTIL THE METER IS REVOLVING.

3. OPEN FULLY THE METER OUTLET VALVE.

4. OPEN FULLY THE METER INLET VALVE.

5. CLOSE THE BY-PASS VALVE.

INSTALLATIONS WITHOUT BY-PASS

1. OPEN METER OUTLET VALVE, SLOWLY.

2. VERY SLOWLY, CRACK METER INLET VALVE UNTIL THE METER IS REVOLVING.

3. VERY SLOWLY, OPEN FULLY THE METER INLET VALVE.

USE OF ORIFICES

To reduce the possibility of damage to positive displacement meters due to rapid opening of the valves, it is suggested that orifices be installed, close to the meter, and on the downstream side of the meter. The meter should be protected from damage due to pressurization by slowly opening (cracking open) the block valve until the system is pressurized. Orifices and nozzles provide protection from meter over-speeding. The following table gives the approximate diameter of orifices which experience has indicated may be satisfactorily used with various sizes of meters.

ORIFICES FOR POSITIVE DISPLACEMENT METERS

Meter Type Rated Gas* Capacity at ½” Differential Rated Gas* Capacity at 2” Differential Orifice Diameter

AL-800 800 CFH 1,700 CFH 0.52”

AL-1000 1,000 CFH 2,200 CFH 0.59”

AL-1400 1,400 CFH 3,000 CFH 0.68”

...

Descargar como (para miembros actualizados) txt (8 Kb)
Leer 4 páginas más »
Disponible sólo en Clubensayos.com