Comments on the MAKO Cell site provided by E//

General Comment:

  • Who should deliver the required H-Frames?
  • When can we get the final decision on this?
  • Can the tilts be define per band?

Example like CUR040.

We putted per cell site survey received some comments below.

CUR013

  1. About new H frame antenna bracket: Instead of installing new H frame below the platform, why can the new antennas not be installed on the existing platform? (Page 12)
  2. The tower used to have a second platform installed at 33 meters. The tower load/structure analysis is not necessary.

CUR015

  1. Page 18 (1.1): TX table MW link to CUR031 is not correct. Information in the document is for link to CUR005 should be 10 degree for going to CUR031
  2. Proposed new equipment is to CUR005. There is no MW link to CUR006.
  3. P19 (1.2):  TX table MW link to CUR005 is not correct. This is the link going to CUR040. The proposed new equipment is to CUR006 is also wrong
  4. Antenna info. New antenna tilts are set TBD. Page 6 This need to be corrected

CUR034

  1. Page 19: Why new grounding bar required MTGB? There are enough free slots available existing bar.
  2. Antenna information:
  3. Why not installing the new antenna at 30m existing antenna height. Page 12 is saying 22M (Picture Antenna at 22M)

CUR030

  1. Page 2: This site is a Digicel site and not colocation with UTS.
  2. Page 12: Why new MW to Parera has to be relocated at 24 m? If we do this it will impact the O&M team to change RAU in case of failure
  3. Page 6: Antenna info. Azimuth 900/700 aren’t the same with 850/1800/2100. Why

CUR031

  1. CW summary

Page 19:[pic 1]Why are 5 new poles needed for MW antennas? If this site only has 1 MW

  1. [pic 2]

This is not correct. Site is outdoor and CUR030 is Sunset Heights and not Coral Estate

  1. Page 6: Antenna info. Sector A must be 295 degrees and not 330 degree

CUR035

  1. Page 2: section 1 Site is a collocated with UTS. Access needed from UTS.
  2. Page2: Existing technology is 3 GSM(900) and 3WCDMA (2100) and not 3 GSM (1800)
  3. Page 3: Section 5 Review existing transmission equipment RJ45 0 free and Optical Free 0 free
  4. TX equipment installation data. Review antenna azimuth and height. There is inconsistency on Page 10 and Page 12 on the height of the MW
  5. Page 18: (1.1) MW height is not correct
  6. Page 6: Antenna Sector C must be 220 degree and not 170 degree
  7. Page 7: Antenna tilts are set to TBD. This must be filled

CUR040

  1. Page 6: Antenna High to be checked not matching

...