This manual contains information concerning the installation, operation and maintenance
of the Vantage 2210/2220. To ensure proper performance of the unit, the instructions
should be thoroughly understood and followed.
Keep the manual in a readily accessible location for future reference.
Changes and additions to the original edition of this manual will be covered by a
“CHANGE NOTICE” supplied with the manual. The change notice will identify the sections in this
manual where the changes have occurred.
Vantage 2210/2220
Table of Contents
General Specifications ................................................................................................... 1-2
General Description....................................................................................................... 1-3
Installation Procedure ................................................................................................. 2-1
Enclosure Mounting....................................................................................................... 2-1
Sensor Mounting ........................................................................................................... 2-2
Wiring Connections ....................................................................................................... 2-3
Splice Procedure............................................................................................................ 2-4
Programming............................................................................................................... 3-1
QuikCal Menu Functions ............................................................................................... 3-1
Program.................................................................................................................... 3-2
Level Mode............................................................................................................. 3-2
Flow Mode.............................................................................................................. 3-3
Totalizer ................................................................................................................. 3-5
4-20 Output ............................................................................................................. 3-6
Setpoints ................................................................................................................. 3-6
Sensor Calibration ................................................................................................... 3-6
Damping................................................................................................................. 3-7
Lost Echo................................................................................................................ 3-7
Flow Simulation ...................................................................................................... 3-7
Integrator ................................................................................................................ 3-7
Pump Alternation .................................................................................................... 3-7
Relay Assignment.................................................................................................... 3-8
Status ........................................................................................................................ 3-8
Data Logger.............................................................................................................. 3-9
System Setup............................................................................................................. 3-10
Calibration ............................................................................................................... 3-11
Sensor Mounting for Primary Elements ...................................................................... 3-12
Parts List..................................................................................................................... 3-17
Section 1
1-1 942001
01/03
Vantage 2200
General Specifications
Span Range
FB4: 0 to 30 feet. Maximum total range including offset distance is 31 feet.
Minimum offset 1 foot.
FB2: 0 to 15 feet. Maximum total range including offset distance is 16 feet.
Minimum offset 1 foot.
FB3: 0 to 50 feet. Maximum total range including offset distance is 52 feet.
Minimum offset 2 feet.
Outputs
4-20 mADC isolated; 1000 ohms max.
Five programmable relays, SPDT .25 amp @ 120 VAC, .5 amp @ 24 VDC.
RS-232 Serial Port, 9600 – 36500 Baud, Modbus™ Protocol
RS-485 Serial Port optically isolated, Modbus™ Protocol (2220 only)
Display 4 line, 20 character per line backlit LCD display.
Programming Front panel mounted 16 button keypad.
Power 90/240 VAC, 50/60 Hz, or 12 VDC @ 150 mA continuous.
Accuracy
FB4: +/- 0.02" or +/- 0.05% of target distance
FB2: +/- 0.02" or +/- 0.05% of target distance
FB3: +/- 0.08" or +/- 0.1% of target distance
Sensors
FB4:
Temperature Range: -20° to 160° F (-30° to 70° C) 50 kHz
Operating Frequency: 60 KHz
Beam Angle: 6° included at -3dB Boundary
Housing: PVC body, PVC cap
Cable: 2 twisted pair, foil shielded, standard lengths of 32 feet
(10 meters) or 65 feet (20 meters). May splice up to
1000 ft maximum of Belden 8728 or equal
FB2:
Temperature Range: -20° to 160° F (-30° to 70° C) 50 kHz
Operating Frequency: 51 KHz
Beam Angle: 8° included at -3dB Boundary
Housing: Tefzel™ body, Teflon™ cap
Cable: 2 twisted pair, foil shielded, standard lengths of 32 feet
(10 meters) or 65 feet (20 meters). May splice up to
1000 ft maximum of Belden 8728 or equal
FB3:
Temperature Range: -40° to 200° F (-40° to 90° C) 30 kHz
Operating Frequency: 30 KHz
Beam Angle: 14° included at –3dB Boundary
Housing: Glass filled polyester / Glass reinforced epoxy face
Cable: 100 feet of 2 twisted pair, foil shielded. May splice up
to 300 ft maximum of Belden 8728 or equal.
*Cable lengths over 300 feet require adding an inductor to sensor terminals.
See sensor wiring section for component description.
Electronic
Enclosure
IP66/NEMA 4X standard, temperature range: -4° to 158° F (-20° to 70° C)
Optional with heater, temperatures down to -40° F (-40°C)
Optional Modem 14400 BBS data speed
1-2
Vantage 2200
General Description
The following description applies to both the Vantage 2210 and 2220.
The Vantage 2200 is an ultrasonic level/flow meter. Its' design allows it to be easily programmed as a
level meter or an open channel flow meter. It can operate two ultrasonic sensors and can be
programmed for two level applications, two flow applications or one level and one flow application.
The Vantage 2200 is supplied with a backlit LCD display with 4 lines and 20 characters per line. In the
normal mode the display has two pages with up to 4 lines that can be assigned to each page. The pages
are switched by pressing the UP/NEXT key. The information for each line can be assigned and
arranged at the users discretion. The backlight of the display can be programmed on or off or timed off.
The programming of the unit is accomplished with the 16 button keypad by means of a drill down type
menu structure. The meter stores the steps taken when it was previously programmed. So when a
programming parameter needs to be changed, the user can quickly get to the screen to make the change.
The display screens can be viewed in three languages: English, Spanish and German.
The Vantage 2200 can be programmed to operate on four different types of sensors. The standard
sensors used with the meter are the FB2, FB3 and FB4. The FB2 sensor is normally used for flow or
level measurements up to 15 feet. The FB4 sensor is used for flow or level
...