This manual contains information concerning the installation, operation and maintenance

of the Vantage 2210/2220. To ensure proper performance of the unit, the instructions

should be thoroughly understood and followed.

Keep the manual in a readily accessible location for future reference.

Changes and additions to the original edition of this manual will be covered by a

“CHANGE NOTICE” supplied with the manual. The change notice will identify the sections in this

manual where the changes have occurred.

Vantage 2210/2220

Table of Contents

General Specifications ................................................................................................... 1-2

General Description....................................................................................................... 1-3

Installation Procedure ................................................................................................. 2-1

Enclosure Mounting....................................................................................................... 2-1

Sensor Mounting ........................................................................................................... 2-2

Wiring Connections ....................................................................................................... 2-3

Splice Procedure............................................................................................................ 2-4

Programming............................................................................................................... 3-1

QuikCal Menu Functions ............................................................................................... 3-1

Program.................................................................................................................... 3-2

Level Mode............................................................................................................. 3-2

Flow Mode.............................................................................................................. 3-3

Totalizer ................................................................................................................. 3-5

4-20 Output ............................................................................................................. 3-6

Setpoints ................................................................................................................. 3-6

Sensor Calibration ................................................................................................... 3-6

Damping................................................................................................................. 3-7

Lost Echo................................................................................................................ 3-7

Flow Simulation ...................................................................................................... 3-7

Integrator ................................................................................................................ 3-7

Pump Alternation .................................................................................................... 3-7

Relay Assignment.................................................................................................... 3-8

Status ........................................................................................................................ 3-8

Data Logger.............................................................................................................. 3-9

System Setup............................................................................................................. 3-10

Calibration ............................................................................................................... 3-11

Sensor Mounting for Primary Elements ...................................................................... 3-12

Parts List..................................................................................................................... 3-17

Section 1

1-1 942001

01/03

Vantage 2200

General Specifications

Span Range

FB4: 0 to 30 feet. Maximum total range including offset distance is 31 feet.

Minimum offset 1 foot.

FB2: 0 to 15 feet. Maximum total range including offset distance is 16 feet.

Minimum offset 1 foot.

FB3: 0 to 50 feet. Maximum total range including offset distance is 52 feet.

Minimum offset 2 feet.

Outputs

4-20 mADC isolated; 1000 ohms max.

Five programmable relays, SPDT .25 amp @ 120 VAC, .5 amp @ 24 VDC.

RS-232 Serial Port, 9600 – 36500 Baud, Modbus™ Protocol

RS-485 Serial Port optically isolated, Modbus™ Protocol (2220 only)

Display 4 line, 20 character per line backlit LCD display.

Programming Front panel mounted 16 button keypad.

Power 90/240 VAC, 50/60 Hz, or 12 VDC @ 150 mA continuous.

Accuracy

FB4: +/- 0.02" or +/- 0.05% of target distance

FB2: +/- 0.02" or +/- 0.05% of target distance

FB3: +/- 0.08" or +/- 0.1% of target distance

Sensors

FB4:

Temperature Range: -20° to 160° F (-30° to 70° C) 50 kHz

Operating Frequency: 60 KHz

Beam Angle: 6° included at -3dB Boundary

Housing: PVC body, PVC cap

Cable: 2 twisted pair, foil shielded, standard lengths of 32 feet

(10 meters) or 65 feet (20 meters). May splice up to

1000 ft maximum of Belden 8728 or equal

FB2:

Temperature Range: -20° to 160° F (-30° to 70° C) 50 kHz

Operating Frequency: 51 KHz

Beam Angle: 8° included at -3dB Boundary

Housing: Tefzel™ body, Teflon™ cap

Cable: 2 twisted pair, foil shielded, standard lengths of 32 feet

(10 meters) or 65 feet (20 meters). May splice up to

1000 ft maximum of Belden 8728 or equal

FB3:

Temperature Range: -40° to 200° F (-40° to 90° C) 30 kHz

Operating Frequency: 30 KHz

Beam Angle: 14° included at –3dB Boundary

Housing: Glass filled polyester / Glass reinforced epoxy face

Cable: 100 feet of 2 twisted pair, foil shielded. May splice up

to 300 ft maximum of Belden 8728 or equal.

*Cable lengths over 300 feet require adding an inductor to sensor terminals.

See sensor wiring section for component description.

Electronic

Enclosure

IP66/NEMA 4X standard, temperature range: -4° to 158° F (-20° to 70° C)

Optional with heater, temperatures down to -40° F (-40°C)

Optional Modem 14400 BBS data speed

1-2

Vantage 2200

General Description

The following description applies to both the Vantage 2210 and 2220.

The Vantage 2200 is an ultrasonic level/flow meter. Its' design allows it to be easily programmed as a

level meter or an open channel flow meter. It can operate two ultrasonic sensors and can be

programmed for two level applications, two flow applications or one level and one flow application.

The Vantage 2200 is supplied with a backlit LCD display with 4 lines and 20 characters per line. In the

normal mode the display has two pages with up to 4 lines that can be assigned to each page. The pages

are switched by pressing the UP/NEXT key. The information for each line can be assigned and

arranged at the users discretion. The backlight of the display can be programmed on or off or timed off.

The programming of the unit is accomplished with the 16 button keypad by means of a drill down type

menu structure. The meter stores the steps taken when it was previously programmed. So when a

programming parameter needs to be changed, the user can quickly get to the screen to make the change.

The display screens can be viewed in three languages: English, Spanish and German.

The Vantage 2200 can be programmed to operate on four different types of sensors. The standard

sensors used with the meter are the FB2, FB3 and FB4. The FB2 sensor is normally used for flow or

level measurements up to 15 feet. The FB4 sensor is used for flow or level

...