ClubEnsayos.com - Ensayos de Calidad, Tareas y Monografias
Buscar

Manual


Enviado por   •  25 de Agosto de 2015  •  Informes  •  460 Palabras (2 Páginas)  •  104 Visitas

Página 1 de 2

[pic 1][pic 2][pic 3][pic 4][pic 5][pic 6]

[pic 7]

1

2

ON        3

1 - CPU ON LED

 _        

  1. - Power ON LED
  2. - Object detection LED

12345678        6

 _        

4 – Not used 5 – Unit testing

6 - Protection cover Fixing holes

6

4

5

Selector Functions

Dip 1        OFF= Update mode        ON= Operating mode

Dip 2,3        DIP 3        DIP 2        RS-485 baud rate

ON        ON        115200 baud

ON        OFF        38400 baud

OFF        ON        19200 baud

OFF        OFF        9600 baud

Dip 4,5,6        Vision System ID        ( B trough I )

Dip 7        OFF= Mean Value Detection        ON= Peak Value Detection


[pic 8][pic 9][pic 10]

[pic 11]

Main characteristics        

[pic 12]

Power supply voltage

24V ( 15VDC - 30VDC)

Current consumption ( 24V )

180mA

Sensor type

CCD 2048 pixels

Spectral response

400 nm – 700nm

Output type

PNP ( NPN as option )

Signals

Red LED        - Power ON Signal

Yellow LED        - Detect object Signal

Green LED        - Blinking CPU Working

Basic sensitivity adjustment

By means of internal lens diaphragm

Baud Rate Programming

By means of Dip 2, 3 of Selector unit, accessible from the case bottom. See SELECTOR FUNCTIONS on first page.

Vision System ID

By means of Dip 4, 5, 6 of Selector unit, accessible from the case bottom. See SELECTOR

FUNCTIONS on first page.

Type of lenses being used

50 mm NIKON lenses (other types of lenses for different framings are available on request)

Available focal lenses upon request

28 mm  - 100 mm -  200 mm

Focusing

By means of focus ring on the lens

Minimum focusing distance

400mm  (200mm with additional lenses)

Framed field (50 mm lenses)

240mm a 500 mm distance from the object

Protections

Reverse polarity protection

Anti splashes frontal protection on request

Extended temperature range housing on request

Anti condensing function on request

Connection

12-pin TRIDENT male panel connector

Unit cooling

Housing provided with hermetically sealed water-air cooling or heating circuit with ¼” GAS threads on the rear side

Working temperature range

0°C ÷ + 40°C with water or air cooling the range can be extended

Storing temperature range

- 20°C ÷ + 70°C

...

Descargar como (para miembros actualizados)  txt (2.5 Kb)   pdf (180.7 Kb)   docx (145.8 Kb)  
Leer 1 página más »
Disponible sólo en Clubensayos.com