ClubEnsayos.com - Ensayos de Calidad, Tareas y Monografias
Buscar

ECG BIPOLAR


Enviado por   •  4 de Noviembre de 2022  •  Tareas  •  1.703 Palabras (7 Páginas)  •  48 Visitas

Página 1 de 7

[pic 1]

ECG BIPOLAR

ALUMNO

KAREN VALENTINA MUÑOZ RIASCOS

1010007914

DOCENTE

ING. JAVIER VILLAMIZAR PINZÓN M.Sc

UNIVERSIDAD MANUELA BELTRÁN

INGENIERÍA BIOMÉDICA

LABORATORIO DE EQUIPOS DE DIÁGNOSTICO

BOGOTÁ D.C.

2021

CONTENIDO

                                                                                                              Pág.                                                                                  

RESUMÉN……………………. ……………………………………...04

ABSTRACT……………………………………………………………05

  1. OBJETIVOS……………………………………………………………06

  1. OBJETIVO GENERAL………………………………………..06
  1. MARCO TEÓRICO…………………………………………………....07
  1. MATERIALES…….…………………………………………………....13
  1. ANÁLISIS…….…………………………………………………………14                                                                
  1. ANÁLISIS  MATEMÁTICO…….……………………………….14
  1. ANÁLISIS EXPERIMENTAL …….……………………………17
  1. ANÁLISIS DE RESULTADOS…………………………………25          
  1. CONCLUSIÓN…………………………………………………………..27
  1. RECOMENDACIONES…………………………………………………28

LISTA DE FIGURAS

Figura  1. Derivaciones bipolares        10

Figura  2. Red de wilson        11

Figura  3 Filtro rechaza banda NOTCH.        12

Figura  4. Optoacoplador 4N28        13

Figura  5. Derivación final I (rosada = final, azul= salida filtro notch y amarilla= salida después de amplificador operacional)        16

Figura  6.Voltajes y tiempo correspondiente derivación I(rosada = final, azul= salida filtro notch y amarilla= salida después de amplificador operacional)        16

Figura  7. Derivación final II  (rosada = final, azul= salida filtro notch y amarilla= salida de amplificador operacional)        17

Figura  8. .Voltajes y tiempo correspondiente derivación II(rosada = final, azul= salida filtro notch y amarilla= salida después de amplificador operacional)        17

Figura  9. Derivación final III        18

Figura  10. .Voltajes y tiempo correspondiente derivación III(rosada = final, azul= salida filtro notch y amarilla= salida después de amplificador operacional)        18

RESUMEN

En este documento se presenta la determinación de las derivaciones bipolares, llamadas, I, II Y III. Halladas mediante un diseño análogo con componentes básicas cómo resistencias, amplificadores operacionales, formando diferentes conjuntos cómo la red de Wilson, encargada del punto de referencia 0 del cuerpo humano, filtro notch o rechaza banda, encargado de eliminar el ruido de 60Hz, optoacoplador, acople de impedancias, etc. También se puede identificar la importancia de conocer los circuitos integrados internamente, ya que, en el diseño se decide no usar referencia específica de algún amplificador de instrumentación sino de armarlo completamente para lograr un buen tratamiento de la señal.

Palabras clave: Filtro, derivación, análogo, red de Wilson,optoacoplador.

ABSTRACT

This document presents the determination of the bipolar leads, it called, I, II and III. It Found through an analogous design with basic components such as resistors, operational amplifiers, forming different sets such as the Wilson network, it in charges of the reference point 0 of the human body, notch filter or band reject, it in charges of eliminating 60Hz noise, optocoupler, coupling impedances, etc. The importance to knowing the integrated circuits internally can also be identified, since, in the design, it had decided not use a specific reference of an instrumentation amplifier, but rather to assemble it completely to achieve a good signal treatment.

Keywords: Filter, shunt, analog, Wilson network, optocoupler.

  1. OBJETIVOS
  1. OBJETIVO GENERAL

Determinar las derivaciones bipolares mediante un circuito análogo entendiendo el desarrollo del biopotencial del corazón.

  1. MARCO TEÓRICO

El electrocardiograma humano es un registro del comportamiento del corazón, mediante él se logran identificar distintas patologías, teniendo en cuenta diferentes variables, una de ellas la frecuencia cardiaca, el número de veces que se contrae el corazón en un minuto, es decir, las pulsaciones por minutos (PPM) y las derivaciones según sea el tipo de electrocardiógrafo, en este caso se evidenciará el de derivaciones bipolares, las cuales son:[1]

  1. Diferencia de potencial entre brazo derecho y brazo izquierdo. Su vector está en dirección a 0º.[2]
  2. Diferencia de potencial entre brazo derecho y pierna izquierda. Su vector está en dirección a 60º.[2]
  3. Diferencia de potencial entre brazo y pierna izquierdos. Su vector está en dirección a 120º.[2]

Figura  1. Derivaciones bipolares

[pic 2]

Fuente : KEITH WELEY,WD,FACEP:ELSEVIER, Quinta edición, 2017. Disponible en(https://books.google.com.co/books?hl=es&lr=&id=USQmDwAAQBAJ&oi=fnd&pg=PP1&dq=derivaciones+bipolares+ecg&ots=JNj0YTowDa&sig=0HglEXCXM6UjbYBPKcfSmw0sJKI&redir_esc=y#v=onepage&q=derivaciones%20bipolares%20ecg&f=false)

Para realizar este registro son necesarios los electrocardiógrafos específicamente de tres cables, que generalmente están compuestos internamente de :

  1. Red de wilson

Esta red es la encargada de implementar el CTW, es decir, la central terminal de Wilson, la cual se encarga de ser el punto de referencia cero de cuerpo humano, permitiendo la medición de derivaciones bipolares mencionadas anteriormente. Además, en el diseño de esta red es necesario tener resistencia con la característica principal de tener alta precisión, es decir con la menor tolerancia posible, lo cual nos brinda el simulador PROTEUS, evitando fallos en el offset.

...